In combination, the custom side panel and duct design provided a massive noise reduction compared to the stock configuration, particularly in lower fan speed ranges. We have measured around 7 dB(A) lower noise levels at around 50% fan speed, and up to 5 dB(A) lower at higher fan speeds, when compared at the same APU operating temperature.

While the custom side panel with our signature Noctua grill as well as the custom fan duct are not slated for mass production at this point, we are more than happy to share the 3D CAD files for everyone who is looking to make their Framework Desktop run even quieter.

Both the custom side panel and the customised fan ductare available to download at Printables.com for you to 3D-print at home

    • Onomatopoeia@lemmy.cafe
      link
      fedilink
      English
      arrow-up
      1
      ·
      edit-2
      1 month ago

      Like I said, if you use a centrifugal fan it doesn’t restrict airflow.

      Every air handler on the planet uses a centrifugal fan with a filter because they can generate vacuum/pressure.

        • Ajen@sh.itjust.works
          link
          fedilink
          English
          arrow-up
          1
          ·
          1 month ago

          They mean the fan is rated for that amount of restriction, and will still move a decent cfm of air. Regular pc fans will drop cfm very quickly when there’s any restriction.

            • Ajen@sh.itjust.works
              link
              fedilink
              English
              arrow-up
              1
              ·
              1 month ago

              Some fan designs handle restrictions much better than others. PC fans will drop to basically zero airflow with a moderate restriction, while centrifugal fans will still move a decent amount of air with that same restriction.